Davey HS60-08T Home Pressure System With Torrium 2 Pressure Controller
Robust & compact, four stage, centrifugal pump with Torrium2® constant flow control and loss of prime device for automatic water pressure. Designed for medium to large size, single and multi-storey homes.
Ideal for pumping clean, nonvolatile liquids without fibres or solids in such applications as :
- Household water supply
- Irrigation
- Water transfer
- Washing systems
- Pressure boosting
The HS Pressure System consists of a HS pump fitted with a Torrium2® controller. The Torrium2® is supplied connected electrically to the HS pump motor for:
- Easy non-tradesmen installation and assembly
- Positive safety under varied weather conditions
The combination of the high pressures supplied by the multistage HS pump and constant flow control provided by the Torrium2® enables consumers to enjoy the benefits of a strong comfortable shower from a pump that does not cycle plus the reliability of adaptive technology.
The complete HS Pressure System is compact and quiet providing for:
- Easy installation, especially where space is at a premium
- Non-intrusive operation, for consumer enjoyment
- More pressure in home outlets
- Choice of performance options to suit most homes
- Quieter household environment
- Improved waterway clearances to reduce impeller blockages
Motor / power: 760W
Max. flow: 110T/min
Head: 49m
Inlet: 1.25″F / 32mm
Outlet: 1″M / 25mm
Pressure: 490kPa
Body: 304 Stainless Steel
Impeller: Glass filled polycarbonate
Mechanical Seal : Carbon Synthetic
Warranty on pump: 2 Years
All parts of the entire system that are in contact with the water are manufactured from safe, corrosion resistant materials for:
- Consumer confidence that their water supply will be as good coming out as it was going into the system
- Ability to use the HS pressure system on a variety of water qualities
Compliance with the strict requirements of ISO 9001.2000 quality standards ensures consistency of quality of the system.
Davey Torrium 2 Pressure Controller
- Reliable twin stage impeller design
- All stainless steel construction for reliability and the ability to pump hot water up to 80°C
- Carbon/Ceramic mechanical seal for reliable pump operation
Motor:
- TEFC motor constructed from corrosion resistant materials
- IP55 international protection rating for a high level of resistance to dust and liquid entry
- Voltage variants:
220-240V, 50Hz, 2 pole
220V, 60Hz, 2 pole (/P models) - Class F insulation
- Higher than normal 55°C ambient temperature rating for longer life and improved tolerance to voltage variations for peace of mind, even on the hottest days.
- Protected against both high operating temperature and high current draw by a built-in, automatically re-setting, thermal overload
- Permanently split capacitor for reliable starting even in low voltage circumstances
- Motor and pump are designed for frequent starts
Constant Flow and Even Water Pressure
To prevent annoying fluctuations in water temperature during showers, Torrium®2 uses its intelligence to provide households with constant flow to give even water pressure. It does this with its innovative pressure and flow sensors to start the pump on a pressure drop and to stop it on low flow (~1 lpm). This avoids pump cycling when there is continuing household demand for water.
Quick Cut-in for Even Pressure
To give you strong pressure right from the start, Torrium®2 is designed to cut in quickly when it senses demand for water. It cuts in when the pressure has dropped to 80% of the previous top (shut-off) pressure. It uses its intelligence to automatically set this cut-in pressure each time the pump stops. In doing so, it allows the system to automatically accommodate for variations in pump performance or site conditions.
Adaptive Starting
Torrium®2 is clever enough to detect the difference between normal water demand and a small leak in the system, such as a dripping faucet or a leaking cistern. For very low flows, Torrium®2 automatically adapts to reduce the cut-in pressure, which can be as low as 50% of its last shut-off pressure. This significantly reduces pump cycling to improve consumer satisfaction with the system. If normal flow is required in the house (>0.5 lpm), Torrium®2 will sense this and revert to normal mode and initiate an immediate pump start.
Easy Status Check
To easily check the system status, Torrium®2 has three simple LED indicators.
- Red LED – the system is in standby mode
- Green LED – the pump is running
- Yellow LED – fault condition
Pressure Indicator Window
To give a quick guide to the system pressure, Torrium®2 has a pressure indicator window on the side of the inbuilt pressure vessel. If the colour band (green-yellow-red) is mainly green it indicates maximum pressure, whereas mainly red indicates low pressure. This indicator can help to analyse the occurrence of unwanted system leaks. If the colour band indicator is moving slowly towards red this signifies a slow drop in pressure and may indicate a small leak. To give a quick guide to the system pressure, Torrium®2 has a pressure indicator window on the side of the inbuilt pressure vessel. If the colour band (green-yellow-red) is mainly green it indicates maximum pressure, whereas mainly red indicates low pressure. This indicator can help to analyse the occurrence of unwanted system leaks. If the colour band indicator is moving slowly towards red this signifies a slow drop in pressure and may indicate a small leak.
Greater Hydraulic Performance
For better hydraulic performance to supply more pressure with less wasted energy, Torrium®2 has been designed with larger water pathways and no moving parts in the pathways. This performance versus loss equation is especially evident at higher flow rates.
Greater Reliability
To diminish the likelihood of blockages, Torrium®2 is designed with no moving control parts within the water pathways giving greater reliability and performance with varying water quality.
Dry Run Protection and Auto Restart
To protect the pump from damage due to dry running, Torrium®2 stops the pump when it detects a loss of prime (no water supply) situation. To reduce system downtime, the Torrium®2 waits 5 minutes then goes into auto retry mode, whereby it will restart the pump to see if prime can be re-established automatically. An auto restart occurs at 5 minutes, 30 minutes, 1 hour, 2, 4, 8, 16 and 32 hours. Torrium®2 will also restart if it detects flow through the system (e.g. from mains water pressure returning with pressure boosting applications).
Pump Protection – High Water Temperature Cut-out
For added security and longer life, a water over-temperature cut-out provides a second level of protection against closed head operation and repetitive cycling. For water temperatures above 70°C Torrium®2 will shut the pump down and the amber LED will be lit. When the water temperature drops to below 60°C, the Torrium®2 will allow the pump to restart.
Pump Protection – Excessive Electrical Current
To protect the pump motor, Torrium®2 will shut the pump down and indicate a fault if it detects excessive electrical current being drawn. This occurs if the pump motor is subjected to locked rotor or if someone tries to manually override the Torrium®2 by continually holding in the prime button.
Corrosion and Scale Resistance
To allow Torrium®2 to be used with water of varying quality, its flow sensors are mounted on a high grade stainless steel plate with special anti-scaling electronic action, which only turns the flow sensors on during pump operation
Extra Draw off Capacity
To accommodate small leaks and to reduce cycling, Torrium®2 has an in-built spring loaded accumulator for extra draw off capacity. A spring loaded accumulator means low maintenance as there is no need for a pressure vessel with its regular air charging and checking. However, for increased draw off, an optional pressure tank, up to 18 litres, can be mounted on the vertical outlet.
Power Surge Protection for Torrium®2
To protect the Torrium®2 controller from electrical surges and spikes, thus extending its life, it has an in-built metal oxide varistor (MOV). The status of the MOV can be checked in the viewing window on the back of the Torrium®2. The MOV is a sacrificial component and should it be consumed due to repeated power surges or spikes, it will almost always blacken the viewing port. This will indicate a non-warrantable Torrium®2 failure.
Ease of Installation
For ease of installation, the plumbing can be connected to either the vertical or the right angle discharge outlet, which can rotate a full 360°. A spanner, sized to fit the coupling, is included in the box. Also, for increased draw off, an optional pressure tank, up to 18 litres, can be mounted on the vertical outlet.
Electrical Connection
For easy installation, Torrium®2 comes with a 2 metre long power lead, fitted with an Australian three pin plug.