Zenit ZEN-SMF200/2/2-80HT Cast Iron Industrial Drainage Pump
SME Drainage
High efficiency pump suitable for pumping storm water, waste water in small sewer systems, livestock farms, the food industry, agriculture and irrigation. Cast iron construction with stainless steel handle and 1 x Silicon Mechanical Seal
1.5kW, 2.0hp, 240V without float switch, max hd 16.8m, max flow 960L/m, Outlet DN 80mm/2” BSPF
Technical Data:
- Max Flow: 960LT/min
- Max Head: 16.5m
- Horse Power: 2.0HP
- Rated power output (P2): 1.5kW
- Input power (P1): 2.1kW
- Nominal absorbed current (In): 3.7A
- Rated power factor(cos phi): 0.83
- Nominal power frequency (f): 50 Hz
- Rated nominal voltage(Vn): 415 V
- N° phases: 3 ( 3 phase pumps require contractor and overload)
- IPMotor: 68
- ATEX thermal class: T4
- Insulation class: F
Constructive Characteristics:
- Outlet: G2″ DN50 PN10
- Outlet orientation: H (horizontal)
- Type of starting: D
- Weight: 36 kg
- EX cable type: NSSHOU-J 4G1.5 2X0.75
- Standard paint type: Bicomponent epoxy paint
- Maximum acoustic pressure: 70 dB
- Set of standard mechanical seals: Two Silicon carbide mechanical seal (SiC)
Use Limits:
- Maximum operating temperature: 40 °C
- Maximum immersion depth: 20 m
- PH of treated fluid: 6 to 14 pH
- Max starts per hour: 30
Materials:
- Case: Grey Cast Iron – EN-GJL 250 (02)
- Shaft: Stainless Steel – AISI 420 (23)
- Cooling jacket: Not applicable (00)
- Standard gasket: Rubber – NBR (77)
- EX gasket Not applicable (00)
- Nuts and bolts: Stainless Steel – Class A2-70 (42)
- Hydraulic: Grey Cast Iron – EN-GJL 250 (02)
- Impeller: Grey Cast Iron – EN-GJL 250 (02)
- Cutting disk: Not applicable (00)
- Cutter Not applicable (00)
- Grid: Stainless Steel – AISI 304 (20)
Test Limits:
- Density of treated fluid 1 Kg/dm³
- Viscosity of treated fluid 1 mm²/s
1 Year Zenit Warranty